Our Technology
Benefits of GDH-FAD

Interference of Oxygen
We created a cutting-edge test strip with the use of FAD-dependent glucose dehydrogenase (GDH-FAD) enzymes for blood glucose measurements. Compared with glucose oxidase (GOD), GDH-FAD avoids interference from blood oxygen variations.
Coenzyme Specificity
GDH-FAD strip can be applied to most blood samples, from capillary to artery, vein and AST. Meanwhile, the GDH-FAD strip can prevent maltose and galactose interference in blood samples.


Insufficient Blood Volume Detection
Blood volume detection function to prevent incorrect result cause by insufficient blood volume.

Strip for PLUS Series


Meters for PLUS Series

Key Features:
- Insufficient blood volume detection
- Backlight display
- Before/After meal (AC/PC) presetable
- Ketone warning
- Bluetooth / USB(Optional)



Key Features:
- Insufficient blood volume detection
- Before/After meal (AC/PC) presetable
- 150 memory storage
- Mini USB

Key Features:
- Insufficient blood volume detection
- Before/After meal (AC/PC) presetable
- Ketone warning
- Talking function
- RS232



Key Features:
- Easy to use
- Easy to carry
- 150 memory storage
Learn More About Our Products
SPECIFICATIONS |
PLUS One
|
PLUS Mini
|
PLUS Talking
|
PLUS Compact
|
---|---|---|---|---|
Accuracy |
±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
|
±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
|
±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
|
±15mg/dL if < 100mg/dL;±15% if ≧ 100mg/dL
|
Ketone Warning |
Yes
|
Yes
|
Yes
|
No
|
Communication |
Mini USB
|
Mini USB
|
RS232
|
Strip port
|
Power Source |
AAA x 2
|
CR2032 x 1
|
AAA x 2
|
CR2032 x 1
|
Memory Capacity |
1000 sets
|
150 sets
|
450 sets
|
150 sets
|
Day Average |
7, 14, 21, 28, 60, 90 Days
|
No
|
7, 14, 21, 28, 60, 90 Days
|
No
|
Daily Alarm |
4 daily alarms
|
No
|
4 daily alarms
|
No |
Dimension |
96 (L) x 61 (W) x 26 (H) mm
|
103.4 (L) x 28.1 (W) x 15.1 (H) mm
|
95 (L) x 52 (W) x 20 (H) mm
|
43.5(L) x 39.3(W) x 24.2(H) mm
|
Weight |
67.2 g (without battery)
|
31.8g (Without battery)
|
48.8g (Without battery)
|
13g (Without battery)
|
Operation Condition |
10ºC (50ºF) ~ 40ºC (104ºF)
|
10ºC (50ºF) ~ 40ºC (104ºF)
|
10ºC (50ºF) ~ 40ºC (104ºF)
|
10ºC (50ºF) ~ 40ºC (104ºF)
|
Storage Condition |
-20ºC (-4ºF) ~ +60ºC (140ºF); 2ºC (35.6ºF) ~ 30ºC (86ºF) (Strip)
|
-20ºC (-4ºF) ~ +60ºC (140ºF); 2ºC (35.6ºF) ~ 30ºC (86ºF) (Strip)
|
-20ºC (-4ºF) ~ +60ºC (140ºF); 2ºC (35.6ºF) ~ 30ºC (86ºF) (Strip)
|
-20ºC (-4ºF) ~ +60ºC (140ºF); 2ºC (35.6ºF) ~ 30ºC (86ºF) (Strip)
|