Benefits of GDH-FAD
Interference of Oxygen
We created a cutting-edge test strip with the use of FAD-dependent glucose dehydrogenase (GDH-FAD) enzymes for blood glucose measurements. Compared with glucose oxidase (GOD), GDH-FAD avoids interference from blood oxygen variations.
Coenzyme Specificity
GDH-FAD strip can be applied to most blood samples, from capillary to artery, vein and AST. Meanwhile, the GDH-FAD strip can prevent maltose and galactose interference in blood samples.
What is 2 + 2 Bio Technology?
TaiDoc patented 2 + 2 (HCT Interference Compensation; 2 enzymes plus 2 signals) technology uses two different wales on the strips to detect HCT value by AC signal and glucose value by DC signal.
Utilizing AC signal to calculate the hematocrit value in order to compensate the correct value from a small volume, fast and accurate test.
Therefore the hematocrit value can compensate the correct glucose value to increase measurement range.
What is Hematocrit(HCT)?
Hematocrit (HCT) is the percentage of the red blood cells in your blood.
Hematocrit (HCT) level varies between individuals, the normal HCT level for
Benefits of the 2 + 2 Bio Technology
The hematocrit may interfere the reading of blood glucose, the higher HCT level will lead to a lower blood glucose result, and the lower HCT level will lead to a higher blood glucose result.
But with Uright exclusive 2+2 Bio Technology is possible to provide glucose reading according to HCT level of the blood sample, therefore it is suitable for neonate, pregnancy and adult who have different HCT level.
XPER Technology
Gold electrode and Laser Engraving technology
XPER is the cutting edge technology by the integration of material science, biosensor engineering, and biomedical engineering. Stable material as 99.9% gold bricks, can pass the signal faster and more accurately. Sputtering coating membrane make resistance steady, and better accuracy consistency. Laser engraving can precise reaction area, so that the electrode conduction more stable.
XPER Technology applies 2 + 2 Bio Technology and enhances the effectiveness
- Well 1: For Nanopolymer which could measure hematocrit with AC signal
- Well 2: For GDH-FAD which could measure blood glucose with DC signal
To widen the measurement range while hematocrit value can compensate the correct glucose value.
Multi Parameter
TaiDoc Ketone strip
Sample Size | 1.0 μL |
Reaction Time | 10 seconds |
Measurement Range | 0.1 – 8.0 mmol/L |
Hematocrit Range | 10 – 70 % |
Storage condition | 2℃ - 30℃ (35.6℉ - 86.0℉) |
Life time | 6 months (18 when sealed) |
Why Test Ketone?
üYour cells can not use glucose for energy.
üYour body begin to burn fat, this process produce ketone.
üKetone build up in the blood make it more acidic.
üKetoacidosis is serious and dangerous
Medication Cup Technology
How does TaiDoc nebulizer work?
The medication will be pumped up through the ring structure in medication cup. The ring structure can shorten the nebulization process and further enhance the nebulization efficiency. This design offers high nebulization efficiency without increases the noise interference and the size of pump.